Name |
An/Aus (1 bit) |
Operation modus (8 bit) |
Fan speed (8 bit) |
Vanes pos. (8 bit) |
Sanyo-Panasonic |
on=1, off=0 |
auto=0, heat=1,cool=3, dry=5, fan=9 |
auto=60, high=100,medium=75, low=50, stop=0 |
stop=0, swing = 100, pos1=85, pos2=70, pos3=55, pos4=40, pos5=25 |
Hitashi |
on=1, off=0 |
auto=0, heat=1,cool=3, dry=14, fan=9 |
high=3,medium=2, low=1 |
pos1=1, pos2=2, pos3=3, pos4=4, pos5=5 |
Daikin |
on=1, off=0 |
auto=0, heat=1,cool=3, dry=14, fan=9 |
high=100,medium=50, low=25 |
pos1=1, pos2=2, pos3=3, pos4=4, pos5=5 |
Daikin 2 |
on=1, off=0 |
auto=0, heat=1,cool=3, dry=14, fan=9 |
auto=0, max=100, high=80, medium=60, low=40, min=20 |
stop=0, swing =1 (1 bit) |
Mitsubishi |
on=1, off=0 |
auto=0, heat=1,cool=3, dry=5, fan=9 |
ultrahigh=4, high=3,medium=2, low=1 |
stop=0, swing = 100, pos1=85, pos2=70, pos3=55, pos4=40, pos5=25 |
Mitsubishi 2 |
on=1, off=0 |
auto=0, heat=1,cool=3, dry=14, fan=9 |
ultrahigh=4, high=3,medium=2, low=1, auto=0 |
stop=0, swing = 6, pos1=1, pos2=2, pos3=3, pos4=4, pos5=5 |
Zennio |
on=1, off=0 |
auto=0, heat=1,cool=3, dry=14, fan=9 |
auto=0, high=100,medium=60, low=20 |
stop=0, swing =1 (1 bit) |
Toshiba |
on=1, off=0 |
auto=0, heat=1,cool=3, dry=14, fan=9 |
high=100,medium=67, low=33 |
pos1=20, pos2=40, pos3=60, pos4=80, pos5=100 |
Fujitsu |
on=1, off=0 |
auto=0, heat=1,cool=3, dry=14, fan=9 |
high=100,medium=67, low=33, stop=0 |
stop=0, swing =1 (1 bit) |
Panasonic |
on=1, off=0 |
auto=0, heat=1,cool=3, dry=14, fan=9 |
high=100,medium=67, low=33, stop=0 |
stop=0, swing =1 (1 bit) |
Arcelik |
on=1, off=0 |
auto=4, heat=1,cool=0, dry=2, fan=3 |
high=3,medium=2, low=1, auto=0 |
stop=0, swing =1 (1 bit) |